Fitting covers per fitting: counting and sizing
Every insulated elbow and tee needs a cover over its insulation, and on most jobs that cover is a preformed PVC fitting cover. Getting the count and the size right matters: a wrong cover number is a wrong price on every fitting on the line.
Which fittings take a cover
- 90° and 45° elbows: one cover each.
- Tees: one tee cover each, sized on the run.
- Couplings: usually covered by the pipe insulation itself; many estimators don't carry a separate cover.
- Reducers: often handled by the insulation on each side; carry a cover only if your crews install one.
- Valves, strainers and unions: follow the specification. Many specs leave unions uninsulated, and valves often take removable covers or labor rather than a fitting cover.
Sizing: pipe size plus insulation wall
A fitting cover fits over the insulated fitting, so its number depends on two things: the pipe size and the insulation wall. A 1 inch line at a 1 inch wall and the same line at a 1-1/2 inch wall take different covers. Use the fitting cover size chart to look one up.
Copper is not iron
Copper tube's outside diameter is its nominal size plus 1/8 inch, while steel pipe follows the iron pipe size table. At larger sizes that difference changes the cover: at a 1 inch wall, 2 inch iron takes a #11 and 2 inch copper takes a #10. Count copper and iron lines separately.
Counting them from the drawings
- Count elbows and tees on each insulated run, by service and size, as you measure the pipe.
- Include the fittings at drops to fixtures and equipment: a drop usually adds at least one elbow at the top.
- On risers, count the offsets and the fittings where branches leave the riser.
- Group the counts by cover number, since that's how covers are bought.
Tacks and accessories
Covers are held with tacks; two per cover is a common allowance. Outdoors, fittings usually take PVC covers too, unless the specification calls for aluminum fitting covers.
Questions
Do 45s and 90s take the same cover number?
The number is set by pipe size and insulation wall, so a 45 and a 90 on the same line share the number, but they're different products and priced separately.
What about fittings on pipe smaller than the chart?
Pipe below the chart's first row (such as 3/8 inch copper) takes the smallest cover made.