Takeoff by page
Every measured line of the takeoff, grouped by the drawing page it is on, with its points on that page. Draw them over your own rendering of the plans, link a quantity to its place on the sheet, or check it against your own takeoff.
GET /v1/jobs/{id}/takeoff. Before the first takeoff is done it answers 409 with the
job's status.
{
"job_id": "c74f3ef7-…",
"takeoff_version": 1,
"run_id": "ae8c4158-…",
"pages": [{
"page": 1,
"sheet_number": "P1",
"drawing": "Hope 4 Youth - Plumbing Permit.pdf",
"sheet_id": "a3f9…:page:1",
"width": 3024, "height": 2160, "rotation": 0,
"items": [{
"id": "2754e5bf-…",
"service": "HW", "size": "1-1/4\"",
"quantity": 147.2, "unit": "LF",
"item_type": "pipe", "description": "1-1/4\" HW main above ceiling",
"state": "provisional", "work_scope": "new",
"points": [[812.4, 1103.0], [1290.7, 1103.0], [1290.7, 1388.2]],
"pdf_points": [[812.4, 1057.0], [1290.7, 1057.0], [1290.7, 771.8]]
}]
}],
"allowances": [{
"id": "…", "service": "CW", "size": "1/2\"", "quantity": 48.0, "unit": "LF",
"item_type": "pipe", "description": "8 ft drop per pipe at each new or unknown fixture — 6 drops",
"state": "provisional", "work_scope": "new"
}],
"totals": {"scaled_LF": 961.0, "allowance_LF": 96.0, "known_estimate_LF": 1057.0},
"api_version": "2026-11-21"
}
Pages
| Field | What it is |
|---|---|
page | The page number in the PDF (1 is the first page). With several PDFs, the page in
drawing. |
sheet_number | The sheet number printed in the title block (P1, M-201), when it could be read. |
drawing | The file the page is in. |
width, height | The page as displayed, in PDF points (1/72 inch), rotation applied. |
rotation | The page's own rotation in the PDF (0, 90, 180, 270). |
Items
| Field | What it is |
|---|---|
id | The item's id, unique within this takeoff_version. A new version has new
ids: replace a job's items when the version changes (see Keep your system in
sync). |
service | The system code: CW, HW, SA… (see
systems). |
size | The pipe size (3/4") or duct size (24x12, 14"Ø),
or unknown. |
quantity, unit | Feet (LF) for pipe and duct; a count
(EA) for fittings and valves. null when it could not be measured. |
item_type | pipe, duct, fitting, valve… |
state | provisional as read; excluded when your company rules leave it
out of the price (for example pipe that is not insulated, or underground with no specification), or when your
estimator took the line out in the app. Excluded lines are listed so you can show them struck out. |
work_scope | new or existing. |
assumed_size, size_source | Present when no size was printed for the line and one
was assumed, with why (for example connected: the size of the pipe it continues). |
square_feet, location | Duct only: its surface area and indoor or
outdoor. |
trade | Mechanical lines only: ductwork, or the piping trade the line belongs to. |
vertical | Mechanical lines only, when true: a vertical run, whose length is the rise. |
points | Where it is, in the page's displayed coordinates (below). A polyline for pipe and duct, one point for a fitting. |
pdf_points | The same places in the PDF's own user space. |
Coordinates
points are in PDF points from the top-left corner of the page as it is displayed
(the page's rotation applied), x to the right and y down: the way a PDF viewer shows the sheet. To draw a line on
a rendering of the page, scale each point by the rendering's width over width, or use an SVG whose
viewBox is the page and needs no scaling at all.
pdf_points are in the PDF's own user space (origin at the bottom-left of the media box, before
rotation), for tools that annotate the PDF file itself.
Show quantities on your drawings has working code for all three: an SVG overlay with PDF.js in the browser, a page image with Pillow, and PDF annotations with pypdf.
Allowances
Some priced footage has no line on a page: the vertical drop at each fixture, a roof drain's leader down the
building, a riser's height, the refrigerant and condensate runs to units the plans do not draw. These are under
allowances, each with a description that says the rule that made it. With them, the
mechanical items add up to the takeoff the app shows for each system and size.
A job with only ductwork or HVAC piping has no plumbing items: its pages hold the mechanical lines alone. Lines your estimator moved, redrew, resized or took out in the app come back as they left them.
Totals
| Field | What it is |
|---|---|
scaled_LF | Feet measured on the drawings. |
allowance_LF | Feet from allowances: drops, leaders, risers. |
known_estimate_LF | All the feet the takeoff has. |
complete_estimate_LF | The same, or null while some line's length is still
unknown. |
complete_estimate_EA | The count of fittings, valves and other counted items. |
These totals cover the plumbing takeoff. Mechanical lines (duct and HVAC piping) are listed on their pages; sum them from the items. Other totals may appear: ignore the ones you do not use.